Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 944
Filter
1.
Rev. cir. traumatol. buco-maxilo-fac ; 23(2): 17-25, abr./jun 2023. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1537357

ABSTRACT

Introdução: A osteotomia Le Fort I possibilita a correção de deformidades dentofaciais que envolvem o terço médio da face. Para sua fixação, convencionou-se o emprego de quatro mini-placas nos pilares zigomático-maxilar e nasomaxilar. Propôs-se então, a dispensa da fixação do segmento posterior, surgindo questionamentos relacionados à capacidade biomecânica do sistema. Objetivos: Comparar o estresse biomecânico gerado em três meios distintos de fixação da osteotomia Le Fort I frente ao movimento de avanço sagital linear maxilar de 7mm. Metodologia: Trata-se de uma pesquisa experimental laboratorial, utilizando-se da análise de elementos finitos como ferramenta analítica, a fim de constatar qual das técnicas sofrerá maior estresse biomecânico. Resultados: Constatou-se que o estresse biomecânico gerado é maior quando aplicado em 4 pontos do que quando aplicado em apenas 2 pontos. Conclusão: Os resultados obtidos fornecem informações aos cirurgiões sobre a real necessidade do uso de fixação adicional de acordo com o método de fixação planejado. No entanto, deve ser interpretado de forma cautelosa, considerando-se as limitações deste estudo. Sendo assim, uma análise incipiente, que tem como intuito o fornecimento de evidência científica de grande significância.


Introducción: La osteotomía Le Fort I permite la corrección de deformidades dentofaciales que involucran el tercio medio de la cara. Para su fijación se acordó utilizar cuatro miniplacas en los pilares cigomaticomaxilar y nasomaxilar. Entonces se propuso prescindir de la fijación del segmento posterior, planteando interrogantes relacionados con la capacidad biomecánica del sistema. Objetivos: Comparar el estrés biomecánico generado en tres medios diferentes de fijación de la osteotomía Le Fort I frente a un movimiento de avance sagital lineal maxilar de 7mm. Metodología: Se trata de una investigación experimental de laboratorio, utilizando como herramienta analítica el análisis de elementos finitos, con el fin de comprobar cuál de las técnicas sufrirá un mayor estrés biomecánico. Resultados: Se encontró que el estrés biomecánico generado es mayor cuando se aplica en 4 puntos que cuando se aplica solo en 2 puntos. Conclusión: Los resultados obtenidos brindan información a los cirujanos sobre la necesidad real de utilizar fijación adicional de acuerdo al método de fijación planificado. Sin embargo, debe interpretarse con cautela, considerando las limitaciones de este estudio. Por tanto, un análisis incipiente, que pretende aportar evidencias científicas de gran trascendencia.


Introduction: The Le Fort I osteotomy allows the correction of dentofacial deformities involving the middle third of the face. For its fixation, it was agreed to use four mini plates on the zygomaticomaxillary and nasomaxillary pillars. It was then proposed to dispense with the fixation of the posterior segment, raising questions related to the biomechanical capacity of the system. Objectives: To compare the biomechanical stress generated in three different means of fixation of the Le Fort I osteotomy against a 7mm maxillary linear sagittal advancement movement. Methodology: This is an experimental laboratory research, using finite element analysis as an analytical tool, in order to verify which of the techniques will suffer greater biomechanical stress. Results: It was found that the biomechanical stress generated is greater when applied to 4 points than when applied to only 2 points. Conclusion: The results obtained provide information to surgeons about the real need to use additional fixation according to the planned fixation method. However, it should be interpreted with caution, considering the limitations of this study. Therefore, an incipient analysis, which aims to provide scientific evidence of great significance.


Subject(s)
Osteotomy, Le Fort , Finite Element Analysis , Orthognathic Surgery , Fracture Fixation, Internal
2.
Rev. bras. ortop ; 58(1): 42-47, Jan.-Feb. 2023. tab, graf
Article in English | LILACS | ID: biblio-1441348

ABSTRACT

Abstract Objective To compare the clinical results between conservative (CS) and surgical treatment (CXS) of A3 and A4 fractures without neurological deficit. Methods Prospective observational study of patients with thoracolumbar fractures type A3 and A4. These patients were separated between the surgical and conservative groups, and evaluated sequentially through the numeric rating scale (NRS), Roland-Morris disability questionnaire (RMDQ), EuroQol-5D (EQ-5D) quality of life questionnaire, and Denis work scale (DWS) up to 2.5 years of follow-up. Results Both groups showed significant improvement, with no statistical difference in pain questionnaires (NRS: CXS 2.4 ± 2.6; CS 3.5 ± 2.6; p> 0.05), functionality (RMDQ: CS 7 ± 6.4; CXS 5.5 ± 5.2; p> 0.05), quality of life (EQ-5D), and return to work (DWS). Conclusion Both treatments are viable options with equivalent clinical results. There is a tendency toward better results in the surgical treatment of A4 fractures.


Resumo Objetivo Comparar os resultados clínicos entre os tratamentos conservador (CS) e cirúrgico (CXS) das fraturas A3 e A4 sem déficit neurológico. Métodos Estudo prospectivo observacional de paciente com fraturas toracolombares tipo A3 e A4. Esses pacientes foram separados entre os grupos cirúrgico e conservador e avaliados sequencialmente através da escala numérica de dor (NRS), do questionário de incapacidade de Roland-Morris (RMDQ), do EuroQol-5D (EQ-5D) e da escala de trabalho de Denis (DWS) até 2,5 anos de acompanhamento. Resultados Ambos os grupos apresentaram melhora significante, sem diferença estatística nos questionários de dor (NRS: CXS 2,4 ± 2,6; CS 3,5 ± 2,6; p> 0,05), funcionalidade (RMDQ: CS 7 ± 6,4; CXS 5,5 ± 5,2; p> 0,05), qualidade de vida (EQ-5D) e retorno ao trabalho (DWS). Conclusão Ambos os tratamentos são opções viáveis e com resultados clínicos equivalentes. Há uma tendência a melhores resultados no tratamento cirúrgico das fraturas A4.


Subject(s)
Humans , Spinal Fractures/surgery , Treatment Outcome , Conservative Treatment , Fracture Fixation, Internal
3.
Chinese Journal of Applied Clinical Pediatrics ; (24): 693-697, 2023.
Article in Chinese | WPRIM | ID: wpr-990099

ABSTRACT

Objective:To investigate the clinical effect of arthroscopic reduction of tibial intercondylar ridge fractures in children using a 2.0 mm perforated Kirschner wire to establish bone tunnels and the Krackow-" 8" suture.Methods:From January 2018 to December 2020, 24 children (14 males and 10 females, aged 6-15 years) with tibial intercondylar ridge fractures admitted to Children′s Hospital of Nanjing Medical University were retrospectively recruited for analyses.All patients were treated with arthroscopic reduction, non-absorbable Krackow-" 8" suture for the base of the anterior cruciate ligament, and establishment of bone tunnels by 2.0 mm perforated Kirschner wire from the proximal tibial epiphysis for inserting a suture to fix the fractures.The affected limb was immobilized with a cast for 4 weeks, followed by active exercises postoperatively.Knee function was assessed using the Lysholm score and IKDC 2000 subjective score.Knee stability was evaluated using the Lachman test.X-rays were taken at 3 and 6 months postoperatively to evaluate fracture healing.Growth retardation of epiphyseal plate at 2 years of follow-up was assessed by bilateral knee X-rays.Results:All the 24 cases were successfully operated, with the operation time of (63.1±20.2) (40-115) min.All children were followed up for 24-36 months[(28.7±3.4) months]. All children achieved an anatomical reduction of the fracture postoperatively.No complications like fracture displacement, suture rupture, or infection were reported.All fractures healed completely at 3 months postoperatively.At the last follow-up, the Lysholm score and IKDC 2000 subjective score were (94.4±4.8) points and (93.8±5.6) points, respectively.The positive Lachman test was detected in 2 patients.No inhibition of proximal tibial epiphyseal growth was observed.Conclusions:Arthroscopic reduction with non-absorbable Krackow-" 8" suture and establishment of bone tunnels using a 2.0 mm perforated Kirschner wire for the treatment of tibial intercondylar ridge fractures in children has the advantages of simple surgical procedures, minimal invasiveness, which is an effective treatment method.

4.
Journal of Medical Biomechanics ; (6): E030-E036, 2023.
Article in Chinese | WPRIM | ID: wpr-987910

ABSTRACT

Objective To compare the effects of cortical bone trajectory ( CBT) and traditional trajectory ( TT)pedicle screw internal fixation on the range of motion (ROM) and rod system stress of normal and osteoporotic(OP) spines. Methods The L3-S1 finite element models of normal and OP spines were established. The screwrod system with two kinds of trajectory was used for internal fixation of the L4-5 segment, so as to simulate sixphysiological loads, namely, flexion, extension, left / right bending, left / right rotation. The effects of two internalfixation methods on ROMs and maximum equivalent stress of screws in normal and OP spines were compared.Results For both bone conditions, CBT and TT significantly reduced ROM of the fixed segment (L4-5) and theentire segment of lower lumbar spine ( L3-S1). However, the ROM decline of CBT group was slightly smaller than that of TT group, and their ROMs were similar under flexion and extension, but the ROM differences were significant under lateral bending and axial rotation. In addition, for both the normal and OP spine models, themaximum equivalent stress of screws in CBT group was significantly higher than that in TT group. Compared withTT group, the screw stress of CBT group in normal spine model under flexion and extension, lateral bending,axial rotation was increased by 27% , 268% and 58% , respectively. However, when CBT technique was used atthe same time, the OP spine model had a smaller screw stress distribution than the normal spine model.Conclusions Compared with TT technique, CBT technique can achieve higher screw stress under OP conditionand reduce screw stress concentration under normal bone condition. In addition, CBT slightly increases ROMs of each segment, which is conducive to recovery of spinal physiological function after surgery. Lateral bending and axial rotation can produce negative mechanical effects, and these two physiological loads should be avoided.

5.
Chinese Journal of Medical Instrumentation ; (6): 312-316, 2023.
Article in Chinese | WPRIM | ID: wpr-982235

ABSTRACT

This study briefly introduces the revised content of Guidance for Registration of Metallic Bone Plate Internal Fixation System (Revised in 2021) compared to the original guidance, mainly including the principles of dividing registration unit, main performance indicators of standard specification, physical and mechanical performance research, and clinical evaluation. At the same time, in order to provide some references for the registration of metallic bone plate internal fixation system, this study analyzes the main concerns in the review process of these products based on the accumulation of experience combining with the current review requirements.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Biomechanical Phenomena
6.
China Journal of Orthopaedics and Traumatology ; (12): 635-640, 2023.
Article in Chinese | WPRIM | ID: wpr-981747

ABSTRACT

OBJECTIVE@#To investigate the clinical efficacy of femoral neck system(FNS) and three cannulated compression screws(CCS) in the treatment of unstable femoral neck fractures in young adults.@*METHODS@#The clinical data of 52 young and middle-aged patients with unstable femoral neck fractures admitted from August 2018 to August 2021 were reviewed and analyzed. All patients were divided into two groups according to the internal fixation method, 25 cases were treated with FNS fixation, 27 cases were treated with closed reduction and 3 CCS inverted triangular distribution. The operation time, incision length, intraoperative bleeding, hospitalization expenses and fracture reduction quality of two groups were recorded and compared;The patients were followed up regularly after operation. The fracture healing time, complete weight-bearing time and postoperative complications(nonunion, femoral neck shortening, femoral head necrosis) of two groups were compared. The Harris score was used to evaluate hip function 6 months after surgery.@*RESULTS@#The operation was successfully completed in both groups. The patients in FNS group had more bleeding, longer incision length and higher hospitalization cost than CCS group(P<0.01). There ware no significant difference in operation time and Garden index between two groups(P>0.05). Patients in both groups were followed up for 6 to 32 months.The fracture healing time in FNS group was less than that in CCS group, the time of complete weight bearing after surgery was earlier than that in CCS group, and the hip Harris score was higher than that in CCS group (P<0.01). There were no internal fixation fracture complications in two groups during follow-up. In the FNS group, there were 4 cases of avascular necrosis of the femoral head and 2 cases of femoral neck shortening, of which 3 cases underwent total hip replacement due to avascular necrosis of the femoral head. In the CCS group, there were 2 cases of nonunion, 9 cases of avascular necrosis of the femoral head, and 11 cases of femoral neck shortening, among which 5 cases underwent total hip replacement due to nonunion and avascular necrosis of the femoral head.@*CONCLUSION@#With simple operation, rotational stability and angular stability, FNS enables patients to start functional exercise as early as possible and reduces the incidence of postoperative complications of unstable femoral neck fracture. It is a new choice for the treatment of unstable femoral neck fracture in young adults.

7.
China Journal of Orthopaedics and Traumatology ; (12): 614-618, 2023.
Article in Chinese | WPRIM | ID: wpr-981743

ABSTRACT

OBJECTIVE@#To investigate the risk factors of elbow stiffness after open reduction and internal fixation of intercondylar fracture of humerus.@*METHODS@#From March 2015 to February 2019, 120 patients with humeral intercondylar fractures were treated with open fixation including 59 males and 61 females, aged from 25 to 77 years with an average of(53.5±3.2) years. According to the occurrence of elbow stiffness after operation, 120 patients were divided into stiffness group(37 cases) and control group(83 cases). The related factors of elbow stiffness were analyzed by single factor analysis, and the risk of elbow stiffness after internal fixation of humeral intercondylar fracture was analyzed by logistic regression factor.@*RESULTS@#There were 37 cases of elbow stiffness(stiff group), and 83 cases had no elbow stiffness(control group). The incidence of joint stiffness was 30.83%. There were significant differences between the stiffness group and the control group in age, injury energy, fracture to operation time, AO classification of fracture, open injury and postoperative premature or hyperactivity. Multivariate logistic regression analysis showed that age>50 years old, high energy injury, AO classification of fracture, open fracture and postoperative premature or hyperactivity were risk factors for elbow stiffness after internal fixation of humeral intercondylar fracture. The postoperative mobility and Mayo elbow performance score(MEPS) scores of the postoperative stiffness group were lower than those of the non-stiffness group with statistical significance(P<0.05). There were no significant differences in postoperative mobility and MEPS scores between flexion stiffness and rotation stiffness after humeral intercondylar fracture(P>0.05).@*CONCLUSION@#In view of the risk factors of elbow stiffness after internal fixation of humeral intercondylar fracture, reasonable operation plan and rehabilitation strategy should be formulated before operation to minimize the incidence of elbow stiffness.

8.
China Journal of Orthopaedics and Traumatology ; (12): 574-578, 2023.
Article in Chinese | WPRIM | ID: wpr-981735

ABSTRACT

OBJECTIVE@#To analyze the clinical outcomes of mini-plate combined with wireforms in the treatment of Type C distal radial fractures with marginal articular fragments.@*METHODS@#This retrospective study included a total of 10 cases, including 5 males and 5 females, with 6 cases involving the left side and 4 cases involving the right side, of Type C distal radial fractures with marginal articular fragments. The age of the patients ranged from 35 to 67 years old. All patients underwent surgical treatment utilizing mini-plate combined with wireforms for internal fixation.@*RESULTS@#The follow-up period ranged from 6 to 18 months. Complete fracture healing was observed in all cases, with healing times ranging from 10 to 16 weeks. During the entire follow-up period, patients reported high levels of satisfaction with the treatment outcomes, and there were no incidences of incision infection, chronic wrist pain, or wrist traumatic arthritis. At the final follow-up assessment, the Mayo score for the wrist joint ranged from 85 to 95, with 7 cases rated as excellent and 3 cases as good.@*CONCLUSION@#Mini-plate combined with wireforms proves to be an effective fixation method for Type C distal radial fractures with marginal articular fragments. The early initiation of wrist joint exercises, strong fixation, maintenance of proper reduction, minimal complications, and high rates of excellent and good outcomes demonstrate the reliability and efficacy of this treatment approach.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Retrospective Studies , Reproducibility of Results , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Treatment Outcome , Wrist Fractures , Wrist Joint , Bone Plates , Range of Motion, Articular
9.
China Journal of Orthopaedics and Traumatology ; (12): 440-444, 2023.
Article in Chinese | WPRIM | ID: wpr-981712

ABSTRACT

OBJECTIVE@#To compare the clinical efficacy of micro steel plate and Kirschner needle oblique and transverse internal fixation of adjacent metacarpal bone in the treatment of metacarpal diaphyseal oblique fracture.@*METHODS@#Fifty-nine patients with metacarpal diaphyseal oblique fractures admitted between January 2018 and September 2021 were selected as the study subjects and divided into the observation group (29 cases) and the control group (30 cases) based on different internal fixation methods. The observation group was treated with Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones, while the control group was treated with micro steel plate internal fixation. Postoperative complications, operation time, incision length, fracture healing time, treatment cost, and metacarpophalangeal function were compared between the two groups.@*RESULTS@#No incision or Kirschner wire infections occurred in the 59 patients, except for one in the observation group. No fixation loosening, rupture, or loss of fracture reduction occurred in any of the patients. The operation time and incision length in the observation group were (20.5±4.2) min and (1.6±0.2) cm, respectively, which were significantly shorter than those in the control group (30.8±5.6) min and (4.3±0.8) cm (P<0.05). The treatment cost and fracture healing time in the observation group were (3 804.5±300.8) yuan and (7.2±1.1) weeks, respectively, which were significantly lower than those in the control group (9 906.9±860.6) yuan and (9.3±1.7) weeks (P<0.05). The excellent and good rate of metacarpophalangeal joint function in the observation group was significantly higher than that in the control group at 1, 2, and 3 months after operation (P<0.05), but there was no significant difference between the two groups at 6 months after operation (P>0.05).@*CONCLUSION@#Micro steel plate internal fixation and Kirschner wire oblique and transverse internal fixation of adjacent metacarpal bones are both viable surgical methods for treating metacarpal diaphyseal oblique fractures. However, the latter has the advantages of causing less surgical trauma, shorter operation time, better fracture healing, lower cost of fixation materials, and no need for secondary incision and removal of internal fixation.


Subject(s)
Humans , Metacarpal Bones/injuries , Fractures, Bone/surgery , Fracture Fixation, Internal/methods , Bone Wires , Bone Plates , Treatment Outcome
10.
China Journal of Orthopaedics and Traumatology ; (12): 406-413, 2023.
Article in Chinese | WPRIM | ID: wpr-981706

ABSTRACT

OBJECTIVE@#To analyze the causes of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy, summarize the clinical results, and propose preventive measures.@*METHODS@#Retrospective analysis was made on the data of 8 cases of lumbar spondylopathy and vertebral fracture treated by oblique lateral interbody fusion in three medical centers from October 2014 to December 2018. All were female, aged from 50 to 81 years with an average of 66.4 years. Disease types included 1 case of lumbar degenerative disease, 3 cases of lumbar spinal stenosis, 2 cases of lumbar degenerative spondylolisthesis and 2 cases of lumbar degenerative scoliosis. Preoperative dual energy X-ray bone mineral density test showed that 2 cases had T-value >-1 SD, 2 cases had T-value -1 to -2.5 SD, and 4 cases had T-value <-2.5 SD. Single segment fusion was in 5 cases, two segment fusion in 1 case and three segment fusion in 2 cases. Four cases were treated with OLIF Stand-alone and 4 cases were treated with OLIF combined with posterior pedicle screw fixation. Postoperative imaging examination showed vertebral fracture, and all of them were single vertebral fracture. There were 2 cases of right lower edge fracture of upper vertebral body at fusion segment, 6 cases of lower vertebral body fracture at fusion segment, and 6 cases with endplate injury and fusion cage partially embedded in vertebral body. Three cases of OLIF Stand-alone were treated with pedicle screw fixation via posterior intermuscular approach, while one case of OLIF Stand-alone and four cases of OLIF combined with posterior pedicle screw fixation were not treated specially.@*RESULTS@#The 5 cases of initial operation and 3 cases of reoperation did not show wound skin necrosis or wound infection. The follow-up time was from 12 to 48 months with an average of 22.8 months. Visual analogue scale (VAS) of low back pain was preoperative decreased from 4 to 8 points (averagely 6.3 points) and postoperative 1 to 3 points (averagely 1.7 points) at the final follow-up. Oswestry disability index (ODI) was preoperative 39.7% to 52.4% (averagely 40.2%), and postoperative 7.9% to 11.2% (averagely 9.5%) at the final follow-up. During the follow-up, there was no loosening or fracture of the pedicle screw system, and no lateral displacement of the fusion cage;however, the fusion cage at the vertebral fracture segment had obvious subsidence. The intervertebral space height of vertebral fracture segment was preoperaive 6.7 to 9.2 mm (averagely 8.1 mm), and postoperative 10.5 to 12.8 mm (averagely 11.2 mm). The improvement rate after operation was 37.98% compared to preoperative. The intervertebral space height at final follow-up was 8.4 to 10.9 mm (averagely 9.3 mm), and the loss rate was 16.71% compared with that after operation. At the final follow-up, interbody fusion was achieved in all cases except for one that could not be identified.@*CONCLUSION@#The incidence of vertebral fracture during oblique lateral interbody fusion in the treatment of lumbar spondylopathy is lower, and there are many reasons for fracture, including preoperative bone loss or osteoporosis, endplate injury, irregular shape of endplate, excessive selection of fusion cage, and osteophyte hyperplasia at the affected segment. As long as vertebral fracture is found in time and handled properly, the prognosis is well. However, it still needs to strengthen prevention.


Subject(s)
Humans , Female , Male , Spinal Fractures/surgery , Retrospective Studies , Treatment Outcome , Lumbar Vertebrae/surgery , Spondylolisthesis/surgery , Scoliosis , Spinal Fusion/methods
11.
China Journal of Orthopaedics and Traumatology ; (12): 376-380, 2023.
Article in Chinese | WPRIM | ID: wpr-981700

ABSTRACT

OBJECTIVE@#To explore clinical effect of open reduction and internal fixation with Henry's approach butterfly plate in treating double-column Die-punch fractures of distal radius.@*METHODS@#From January 2018 to June 2021, 26 patients with double-column Die-column distal radius were treated with open reduction and internal fixation through Henry's surgical approach and using distal radius volar column plate(butterfly plate), including 14 males and 12 females, aged from 20 to 75 years old with an average age of (44.2±3.4) years old. Postopertaive complications were observed, Gartland-Werley score at 12 months after opertaion was used to evaluate wrist joint function.@*RESULTS@#All 26 patients were followed up from 10 to 18 months with an average of(13.4±0.8) months. All fractures were obtained fracture union, the time ranged from 8.5 to 15.8 weeks with an average of (11.4±0.5) weeks. All incisions healed at stageⅠwithout infection, nerve injury and internal fixation failure occurred. Postoperative Gartland-Werley score at 12 months was (3.65±0.36), and 16 patients got excellent result, 8 good and 2 moderate.@*CONCLUSION@#Open reduction and internal fixation with butterfly plate for the treatment of double-column Die-punch fractures of the distal radius through volar Henry approach could obtain satisfactory clinical outcomes.


Subject(s)
Adult , Aged , Animals , Female , Humans , Male , Middle Aged , Young Adult , Bone Plates , Fracture Fixation, Internal/methods , Radius/surgery , Radius Fractures/surgery , Range of Motion, Articular , Treatment Outcome , Wrist Joint
12.
China Journal of Orthopaedics and Traumatology ; (12): 308-312, 2023.
Article in Chinese | WPRIM | ID: wpr-981688

ABSTRACT

OBJECTIVE@#To explore treatment strategy for complex Schatzker Ⅳ tibial plateau fracture.@*METHODS@#Forty-one patients with complex Schatzker type Ⅳ tibial plateau fractures were treated from January 2016 to January 2021, including 28 males and 13 females, aged from 19 to 65 years old with an average of (35.3±19.8) years old. Individualized treatment plan was developed according to preoperative imaging characteristics, medial surgical approach was mainly combined with other auxiliary incisions. Posteromedial inverted L approach was used in 18 patients, posteromedial approach and anterolateral extended approach in 19 patients, and posteromedial approach with anterolateral and lateral condylar osteotomy in 4 patients. Articular surface and facture healing were observed, range of knee joint motion was measured at 12 months after opertaion, and function of knee joint was evaluated by Lysholm scoring system.@*RESULTS@#Forty-one patients were followed up for 12 to 26 months with an average of (13.3±6.8) months. Twenty-nine patients and 10 patients were obtained complete fracture healing at 6 and 12 months after operation respectively, and fracture healing time was 4 to 13 months with an average of (5.0±3.7) months. Two patients occurred posterior medial internal fixation failure and varus deformity of knee joint, and the fracture healed and varus deformity was corrected after the second operation. Range of knee joint motion was (118±29) °, and Lysholm score was(83.0±16.0) points.@*CONCLUSION@#Individualized treatment should be reasonably selected for complex Schatzker Ⅳ tibial plateau fractures, the characteristics of lateral plateau fractures are an important reference for selecting surgical approaches, the effective fixation of posteromedial bone blocks should be pay full attention, and the overall treatment results are satisfied.


Subject(s)
Male , Female , Humans , Young Adult , Adult , Middle Aged , Aged , Adolescent , Tibial Plateau Fractures , Bone Plates , Tibial Fractures/surgery , Treatment Outcome , Knee Joint/surgery , Fracture Fixation, Internal/methods , Retrospective Studies
13.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 810-814, 2023.
Article in Chinese | WPRIM | ID: wpr-981672

ABSTRACT

OBJECTIVE@#To investigate the effectiveness of sequential plate internal fixation in the correction of Madelung deformity after ulnar osteotomy and shortening.@*METHODS@#The clinical data of 13 patients with Madelung deformity admitted between September 2015 and July 2021 were retrospectively analyzed. There were 5 males and 8 females with an average age of 18.3 years ranging from 17 to 23 years. The disease duration ranged from 12 to 24 months, with an average of 17 months. Three cases had a clear history of trauma. All patients had external radial deviation deformity and limited movement of the ulnar deviation, and the ulnar impact pain was significant during ulnar deviation movement; 9 patients had limited wrist joint supination movement, and the supination movement was normal. In the first stage, ulnar osteotomy and shortening combined with external fixator were used to correct wrist deformity in 13 patients. After operation, bone transfer was performed 6 times per day, with adjustments made every 4 hours, which was 1 mm per day. After the osteotomy was in place, the ulnar plate internal fixation was performed to reconstruct the ulnar stability in the second stage. The Cooney wrist joint score was used to assess the pain, function, range of motion, flexion and extension range of motion, and grip strength of the wrist joint before operation and before the removal of internal fixator. The subjective feeling and appearance satisfaction of patients were recorded.@*RESULTS@#After the second-stage operation, all the 13 patients were followed up 10-22 months, with an average of 15 months. The deformity of wrist joint disappeared after operation, and the flexion, extension, and ulnar deviation were basically normal. There was no complication such as ulnar impingement sign, nonunion or infection. Wrist function, pain, and range of motion were significantly improved after operation, except for 1 patient who had no significant improvement in rotation and pain. The ulnar internal fixator was removed at 10-18 months after the second-stage operation. The scores of pain, function, range of motion, flexion and extension range of motion, and grip strength in the Cooney wrist score before removal of internal fixator significantly improved when compared with those before operation ( P<0.05). Subjective and appearance satisfaction of patients were excellent in 9 cases, good in 3 cases, and fair in 1 case.@*CONCLUSION@#Ulnar osteotomy and shortening with sequential plate internal fixation for correction of Madelung deformity, with mild postoperative pain, can effectively avoid bone nonunion, improve wrist joint function, and have significant effectiveness.


Subject(s)
Male , Female , Humans , Adolescent , Retrospective Studies , Ulna/surgery , Osteochondrodysplasias , Radius Fractures/surgery , Wrist Joint/surgery , Osteotomy , Range of Motion, Articular , Treatment Outcome
14.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 694-699, 2023.
Article in Chinese | WPRIM | ID: wpr-981654

ABSTRACT

OBJECTIVE@#To evaluate the effectiveness of limited internal fixation combined with a hinged external fixator in the treatment of peri-elbow bone infection.@*METHODS@#The clinical data of 19 patients with peri-elbow bone infection treated with limited internal fixation combined with a hinged external fixator between May 2018 and May 2021 were retrospectively analyzed. There were 15 males and 4 females with an average age of 44.6 years (range, 28-61 years). There were 13 cases of distal humerus fractures and 6 cases of proximal ulna fractures. All the 19 cases were infected after internal fixation of fracture, and 2 cases were complicated with radial nerve injury. According to Cierny-Mader anatomical classification, 11 cases were type Ⅱ, 6 cases were type Ⅲ, and 2 cases were type Ⅳ. The duration of bone infection was 1-3 years. After primary debridement, the bone defect was (3.04±0.28) cm, and the antibiotic bone cement was implanted into the defect area, and the external fixator was installed; 3 cases were repaired with latissimus dorsi myocutaneous flap, and 2 cases were repaired with lateral brachial fascial flap. Bone defects repair and reconstruction were performed after 6-8 weeks of infection control. The wound healing was observed, and white blood cell (WBC), erythrocyte sedimentation rate (ESR), and C-reaction protein (CRP) were reexamined regularly after operation to evaluate the infection control. X-ray films of the affected limb were taken regularly after operation to observe the bone healing in the defect area. At last follow-up, the flexion and extension range of motion and the total range of motion of the elbow joint were observed and recorded, and compared with those before operation, and the function of the elbow joint was evaluated by Mayo score.@*RESULTS@#All patients were followed up 12-34 months (mean, 26.2 months). The wounds healed in 5 cases after skin flap repair. Two cases of recurrent infection were effectively controlled by debridement again and replacement of antibiotic bone cement. The infection control rate was 89.47% (17/19) in the first stage. Two patients with radial nerve injury had poor muscle strength of the affected limb, and the muscle strength of the affected limb recovered from grade Ⅲ to about grade Ⅳ after rehabilitation exercise. During the follow-up period, there was no complication such as incision ulceration, exudation, bone nonunion, infection recurrence, or infection in the bone harvesting area. Bone healing time ranged from 16 to 37 weeks, with an average of 24.2 weeks. WBC, ESR, CRP, PCT, and elbow flexion, extension, and total range of motions significantly improved at last follow-up ( P<0.05). According to Mayo elbow scoring system, the results were excellent in 14 cases, good in 3 cases, and fair in 2 cases, and the excellent and good rate was 89.47%.@*CONCLUSION@#Limited internal fixation combined with a hinged external fixator in the treatment of the peri-elbow bone infection can effectively control infection and restore the function of the elbow joint.


Subject(s)
Male , Female , Humans , Adult , Elbow , Elbow Joint/surgery , Retrospective Studies , Bone Cements , Treatment Outcome , External Fixators , Fracture Fixation, Internal/methods , Fractures, Bone , Range of Motion, Articular
15.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 688-693, 2023.
Article in Chinese | WPRIM | ID: wpr-981653

ABSTRACT

OBJECTIVE@#The biomechanical characteristics of three internal fixation modes for femoral subtrochanteric spiral fracture in osteoporotic patients were compared and analyzed by finite element technology, so as to provide the basis for the optimization of fixation methods for femoral subtrochanteric spiral fracture.@*METHODS@#Ten female patients with osteoporosis and femoral subtrochanteric spiral fractures caused by trauma, aged 65-75 years old, with a height of 160-170 cm and a body weight mass of 60-70 kg, were selected as the study subjects. The femur was scanned by spiral CT and a three-dimensional model of the femur was established by digital technology. The computer aided design models of proximal intramedullary nail (PFN), proximal femoral locking plate (PFLP), and the combination of the two (PFLP+PFN) were constructed under the condition of subtrochanteric fracture. Then the same load of 500 N was applied to the femoral head, and the stress distribution of the internal fixators, the stress distribution of the femur, and the displacement of femur after fracture fixation were compared and analyzed under the three finite element internal fixation modes, so as to evaluate the fixation effect.@*RESULTS@#In the PFLP fixation mode, the stress of the plate was mainly concentrated in the main screw channel, the stresses of the different part of the plate were not equal, and gradually decreased from the head to the tail. In the PFN fixation mode, the stress was concentrated in the upper part of the lateral middle segment. In the PFLP+PFN fixation mode, the maximum stress appeared between the first and the second screws in the lower segment, and the maximum stress appeared in the lateral part of the middle segment of the PFN. The maximum stress of PFLP+PFN fixation mode was significantly higher than that of PFLP fixation mode, but significantly lower than that of PFN fixation mode ( P<0.05). In PFLP and PFN fixation modes, the maximum stress of femur appeared in the medial and lateral cortical bone of the middle femur and the lower side of the lowest screw. In PFLP+PFN fixation mode, the stress of femur concentrated in the medial and lateral of the middle femur. There was no significant difference in the maximum stress of femur among the three finite element fixation modes ( P>0.05). The maximum displacement occurred at the femoral head after three finite element fixation modes were used to fix subtrochanteric femoral fractures. The maximum displacement of femur in PFLP fixation mode was the largest, followed by PFN, and PFLP+PFN was the minimum, with significant differences ( P<0.05).@*CONCLUSION@#Under static loading conditions, the PFLP+PFN fixation mode produces the smallest maximum displacement when compared with the single PFN and PFLP fixation modes, but its maximum plate stress is greater than the single PFN and PFLP fixation mode, suggesting that the combination mode has higher stability, but the plate load is greater, and the possibility of fixation failure is higher.


Subject(s)
Humans , Female , Aged , Finite Element Analysis , Biomechanical Phenomena , Fracture Fixation, Internal/methods , Hip Fractures/surgery , Bone Plates , Femur Head , Femoral Fractures/surgery
16.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 681-687, 2023.
Article in Chinese | WPRIM | ID: wpr-981652

ABSTRACT

OBJECTIVE@#To investigate the effectiveness of joystick technique assisted closed reduction and cannulated screw fixation in the treatment of femoral neck fracture.@*METHODS@#Seventy-four patients with fresh femoral neck fractures who met the selection criteria between April 2017 and December 2018 were selected and divided into observation group (36 cases with closed reduction assisted by joystick technique) and control group (38 cases with closed manual reduction). There was no significant difference in gender, age, fracture side, cause of injury, Garden classification, Pauwels classification, time from injury to operation, and complications (except for hypertension) between the two groups ( P>0.05). The operation time, intraoperative infusion volume, complications, and femoral neck shortening were recorded and compared between the two groups. Garden reduction index was used to evaluate the effect of fracture reduction, and score of fracture reduction (SFR) was designed and was used to evaluate the subtle reduction effect of joystick technique.@*RESULTS@#The operation was successfully completed in both groups. There was no significant difference in operation time and intraoperative infusion volume between the two groups ( P>0.05). All patients were followed up 17-38 months, with an average of 27.7 months. Two patients in the observation group received joint replacement due to failure of internal fixation during the follow-up, and the other patients had fracture healing. Within 1 week after operation, the Garden reduxtion index of the observation group was better than the control group; the SFR score of the observation group was also higher than that of the control group; the proportion of femoral neck shortening within 1 week after operation and at 1 year after operation in the observation group were lower than those in the control group. The differences of the above indexes between the two groups were significant ( P<0.05).@*CONCLUSION@#The joystick technique can improve the effectiveness of closed reduction of femoral neck fractures and reduce the incidence of femoral neck shortening. The designed SFR score can directly and objectively evaluate the reduction effect of femoral neck fracture.


Subject(s)
Humans , Treatment Outcome , Bone Screws , Femoral Neck Fractures/surgery , Plastic Surgery Procedures , Fracture Fixation, Internal/methods , Retrospective Studies
17.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 572-577, 2023.
Article in Chinese | WPRIM | ID: wpr-981634

ABSTRACT

OBJECTIVE@#To compare the effectiveness of open reduction of posterior cruciate ligament (PCL) avulsion fracture at tibial insertion of knee joint with absorbable screws fixation and absorbable screw combined with suture anchor fixation.@*METHODS@#The clinical data of 26 patients with PCL avulsion fracture at tibial insertion who met the selection criteria between March 2015 and October 2021 were retrospectively analyzed. Among them, 14 patients were fixed with simple absorbable screw (group A), and 12 patients were fixed with absorbable screw combined with suture anchors (group B). All patients were confirmed by X-ray film, CT, or MRI preoperatively, and got positive results in preoperative posterior drawer tests. There was no significant difference in gender, age, side of affected limb, time from injury to operation, comorbidities, and preoperative Meyers & McKeever classification, Lysholm score, and International Knee Documentation Committee (IKDC) score between the two groups ( P>0.05). The operation time and postoperative complications were recorded and compared between the two groups. At last follow-up, Lysholm score and IKDC score were used to evaluate the improvement of knee function.@*RESULTS@#There was no significant difference in operation time between the two groups ( P>0.05). All incisions healed by first intention, and no complication such as vascular and nerve injury or venous thrombosis occurred. All 26 patients were followed up 9-89 months, with an average of 55.3 months. The follow-up time of group A and group B was (55.7±23.2) and (56.8±29.3) months, respectively, with no significant difference ( t=-0.106, P=0.916). Radiographs showed bone healing in both groups at 3 months after operation, and no complication such as infection and traumatic arthritis occurred. At last follow-up, the posterior drawer test was negative in both groups, and the Lysholm score and IKDC score significantly improved when compared with the pre-operative values ( P<0.05). However, there was no significant difference in the improvement value between the two groups ( P>0.05).@*CONCLUSION@#For PCL avulsion fracture at tibial insertion of the knee joint, the open reduction and absorbable screw combined with suture anchor fixation can achieve reliable fracture reduction and fixation, which is conducive to the early rehabilitation and functional exercise, and the postoperative functional recovery of the knee joint is satisfactory.


Subject(s)
Humans , Posterior Cruciate Ligament/injuries , Suture Anchors , Fractures, Avulsion/surgery , Retrospective Studies , Tibial Fractures/surgery , Arthroscopy/methods , Fracture Fixation, Internal/methods , Knee Joint/surgery , Bone Screws , Suture Techniques , Treatment Outcome
18.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 410-416, 2023.
Article in Chinese | WPRIM | ID: wpr-981607

ABSTRACT

OBJECTIVE@#To investigate the effectiveness of osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation in the treatment of tibial plateau fractures involving posterolateral column collapse.@*METHODS@#A clinical data of 23 patients with tibial plateau fractures involving posterolateral column collapse, who had undergone osteotomy of non-core weight-bearing area of the lateral tibial plateau, reduction, and internal fixation between January 2015 and June 2021, was retrospectively analyzed. There were 14 males and 9 females with an average age of 42.6 years ranging from 26 to 62 years. The causes of injury included traffic accident in 16 cases, falling from height in 5 cases, and other injuries in 2 cases. According to Schatzker classification, there were 15 cases of type Ⅴ and 8 cases of type Ⅵ. The time from injury to operation was 4-8 days with an average of 5.9 days. The operation time, intraoperative blood loss, fracture healing time, and complications were recorded. The depth of articular surface collapse of posterolateral column and posterior inclination angle (PSA) of the tibial plateau were compared before operation and at 2 days and 6 months after operation; fracture reduction of tibial plateau fracture was evaluated by Rasmussen anatomic score. The recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score at 2 days and 6 months after operation.@*RESULTS@#All 23 patients were completed the operation successfully. The operation time was 120-195 minutes, with an average of 152.8 minutes; the intraoperative blood loss was 50-175 mL, with an average of 109.5 mL. All patients were followed up 12-24 months, with an average of 16.7 months. One patient had superficial wound infection after operation, and the incision healed after dressing change; primary healing of incision of other patients was obtained. The fracture healing time was 12-18 weeks, with an average of 13.7 weeks. No failure of internal fixation, varus and valgus deformity of the knee joint, and instability of the knee joint was found at last follow-up. One patient developed joint stiffness and the range of motion of the knee joint was 10°-100°; the range of motion of the knee joint of other patients was 0°-125°. At 2 days and 6 months after operation, the depth of articular surface collapse of posterolateral column, PSA, and Rasmussen anatomic scores significantly improved when compared with those before operation ( P<0.05). There was no significant difference between the two postoperative time points ( P>0.05). The HSS score at 6 months after operation was significantly higher than that at 2 days after operation ( P<0.05).@*CONCLUSION@#For tibial plateau fractures involving posterolateral column collapse, reduction and internal fixation through osteotomy of non-core weight-bearing area of the lateral tibial plateau has the advantages of fully expose the posterolateral column fragment, good articular surface reduction, sufficient bone grafting, and fewer postoperative complications. It is beneficial to restore knee joint function and can be widely used in clinic.


Subject(s)
Male , Female , Humans , Adult , Retrospective Studies , Blood Loss, Surgical , Tibial Plateau Fractures , Treatment Outcome , Bone Plates , Tibial Fractures/surgery , Knee Joint , Fracture Fixation, Internal , Osteotomy , Weight-Bearing
19.
China Journal of Orthopaedics and Traumatology ; (12): 247-250, 2023.
Article in Chinese | WPRIM | ID: wpr-970856

ABSTRACT

OBJECTIVE@#To investigate the clinical effect of double pulley combined with suture bridge in the treatment of comminuted fracture of the lower pole of the patella.@*METHODS@#From January 2018 to June 2020, 15 patients with comminuted fracture of the lower pole of the patella were treated with double pulley and suture bridge technology, including 9 males and 6 females, aged 28 to 68 years old with an average of (42.4±9.6) years old. All patients had obvious knee joint pain and limited movement after injury. All knee joints were examined by X-ray and CT, which confirmed that they were all comminuted fractures at the lower level of the patella. After operation, X-ray films of the knee joint were taken regularly to understand the fracture healing, the Insall Salvati index was measure, the range of motion of the joint was recorded, and the function of the knee joint was evaluateed by the Bostman scoring system.@*RESULTS@#All the 15 patients were followed up for 7 to 24 months with an average of (11.4±4.2) months, and there was no obvious anterior knee pain. At the last follow-up, the knee joint range of motion of the affected limb was 105° to 140° with an average of (128.5±12.8) °, and the Insall Salvati index was 0.79 to 1.12 with an average of (0.92±0.18). The X-ray film showed that the patella was bone healing, and no anchor fell off, broken, or displaced fracture block was found. Bostman patellar fracture function score was 27.85±2.06, 13 cases were excellent, 2 cases were good.@*CONCLUSION@#Double pulley technique combined with suture bridge technique is reliable for reduction and fixation of comminuted fracture of the lower pole of patella, and patients can start functional exercise early after operation.


Subject(s)
Male , Female , Humans , Adult , Middle Aged , Aged , Fractures, Comminuted/surgery , Fracture Fixation, Internal/methods , Patella/injuries , Bone Wires , Fractures, Bone/surgery , Sutures , Treatment Outcome
20.
China Journal of Orthopaedics and Traumatology ; (12): 242-246, 2023.
Article in Chinese | WPRIM | ID: wpr-970855

ABSTRACT

OBJECTIVE@#To investigate the relationship between the shape of the lateral wall and the early failure of internal fixation in the fracture of the femoral trochanteric region(FFT).@*METHODS@#Total 295 patients with femoral trochanteric fracture underwent internal fixation from January 2015 to January 2020 were selected. The patients were divided into two groups according to whether there was early internal fixation failure after surgery, 19 patients in the failure group and 276 patients in the normal group. Gender, affected side, age, AO classification, body mass index(BMI), preoperative hemoglobin, X-ray measurement of lower lateral wall thickness, preoperative internal diseases, intraoperative blood loss, postoperative tip apex distance(TAD), postoperative neck shaft angle, operation time and other data were compared between two groups. The shape of the lateral wall was compared between two groups, and the correlation between the shape of the lateral wall and the early internal fixation failure of femoral trochanteric fracture was analyzed.@*RESULTS@#All patients were followed up for more than 1 year. There was no significant difference between two groups in terms of intraoperative blood loss, operation time, postoperative TAD, and postoperative neck shaft angle(P>0.05). At the latest follow-up, the visual anaglue scale (VAS) of the failure group was higher than that of the normal group(P<0.01), and the Harris score of the failure group was lower than that of normal group(P<0.05). The receiver operator characteristic (ROC) curve between shape of lateral wall and failure of early internal fixation of femoral trochanteric fracture was drawn. The critical value of the midpoint lateral wall thickness was 16.5 mm, and the area under the ROC curve was 0.845;The critical value of average sidewall thickness was 16.5 mm, and the area under ROC curve was 0.838;The critical value of the axial area of the sidewall was 7.5 mm, and the area under the ROC curve was 0.826.@*CONCLUSION@#The shape of the lateral femoral wall measured by CT could be used as a predictive factor for the early failure of internal fixation of femoral trochanteric fractures. For patients at risk, more reasonable surgical plans and postoperative preventive measures should be developed.


Subject(s)
Humans , Treatment Outcome , Fracture Fixation, Intramedullary , Bone Nails , Retrospective Studies , Hip Fractures/surgery , Fracture Fixation, Internal
SELECTION OF CITATIONS
SEARCH DETAIL